EMC testing and troubleshooting
We measure electromagnetic interference or EMI. We measure EMI-related malfunctions and do Pre-compliance EMC testing. Both emission and immunity tests.
What kind of measurements?
Lemcko can help you with the following EMC problems:
- Pre-compliance testing on prototypes
- Optimize EMC design
- EMC assessment on (large) machines
- Solving communication problems (including industrial networks)
- Solving power electronics related problems (including overvoltages on motors, bearing currents and EMI)
- Standard study
Testing equipment
Our semi-anechoic EMC room is immobile. Our other equipment can measure the following standards, also on travel: pre-compliant (P) and full-compliant (F):
- Emission (P):
- EN61000-6-1 to 6-4, EN55011, EN55015, EN55022, EN55032
- 9 kHz to 6 GHz
- Immunity (F): EN61000-4-2, 4-3, 4-4, 4-5, 4-6
- 20 V / m over the entire frequency range
- 30 MHz to 1 GHz
- Up to 5 kV (surge and EFT / B)
- Up to 15 kV (ESD)